S95 Fitness Certificate Practice Test

S95 Building Fire Alarm Fitness Certification Test You will need a practice test that will test your knowledge and understanding of the test.

See Answer Key
  1. What is the primary purpose of fire alarm systems in protected premises?
    A. To monitor building temperature levels
    B. To control building access remotely
    C. To warn occupants and signal FDNY
    D. To manage the building’s plumbing
  2. Which Certificate of Fitness holder is required for a fire alarm system without voice
    communication, if no FLSD or F-80 is required?
    A. S-95 Supervision holder needed
    B. S-12 Sprinkler holder needed
    C. F-01 Fire Guard holder needed
    D. S-97 Alarm Technician needed
  3. What does a supervisory signal typically indicate?
    A. An active fire emergency event
    B. A system needs routine cleaning
    C. The building power has failed
    D. A monitored system is compromised
  4. What action should be taken upon receiving a trouble signal?
    A. Investigate and correct the fault
    B. Reset the fire alarm panel quickly
    C. Notify FDNY for immediate response
    D. Immediately evacuate the entire building
  5. How often must standard smoke detectors be cleaned?
    A. Cleaned at least once weekly
    B. Cleaned not less than monthly
    C. Cleaned every six months minimum
    D. Cleaned only when visibly dirty
  6. Who is authorized to perform smoke detector cleaning and testing?
    A. Any S-95 certificate holder
    B. Only the building owner personally
    C. The designated impairment coordinator
    D. Holders of S-78, S-97, or S-98
  7. What is the maximum time allowed for fire alarm output functions to operate after
    smoke detector activation?
    A. Operation within 5 seconds maximum
    B. Operation within 30 seconds maximum
    C. Operation within 10 seconds maximum
    D. Operation within 60 seconds maximum
  8. Where must manual fire alarm boxes (pull stations) be located?
    A. Located only on the first floor
    B. Located hidden within utility closets
    C. Located inside locked security offices
    D. Located near exits, conspicuous, accessible
  9. What color must manual fire alarm boxes be in NYC?
    A. Must be red in color
    B. Must be safety orange color
    C. Must be standard blue color
    D. Must be bright yellow color
  10. What must be done before resetting a fire alarm system after activation?
    A. Silence the audible alarms first
    B. Notify the central station only
    C. Check the secondary power source
    D. Ensure the initiating device is reset
    Answer Key:
    -1. C
    -2. A
    -3. D
    -4. A
    -5. C
    -6. D
    -7. C
    -8. D
    -9. A
    -10. D
  11. What is the primary function of an annunciator panel?
    A. To visually indicate system status
    B. To initiate manual fire alarms
    C. To silence building alarm sounds
    D. To directly extinguish small fires
  12. How often must two-way communication systems (warden phones) be tested?
    A. Tested on a weekly basis
    B. Tested at least annually
    C. Tested on a monthly basis
    D. Tested only during emergencies
  13. What information is required at the beginning of the alarm log book?
    A. Only the building name listed
    B. Just the C of F holder’s name
    C. Fire drill schedule dates only
    D. Premises address, system details, contacts
  14. What is the retention period for alarm log books?
    A. Retained for one year only
    B. Retained for three years minimum
    C. Retained for two years only
    D. Retained for five years minimum
  15. When taking a fire alarm system offline for testing, who must be notified first?
    A. Notify only the building manager
    B. Notify the FDNY borough dispatch
    C. Notify all building occupants directly
    D. Notify the approved central station
  16. What is required if a mandatory fire protection system is out of service?
    A. Post warning signs on doors
    B. Temporarily close the affected area
    C. Notify FDNY and implement fire watch
    D. Reduce building occupancy slightly
  17. Who is responsible for ensuring safety precautions when a fire protection system is out
    of service?
    A. The first responding firefighter
    B. Any available security guard
    C. The central station operator
    D. The designated Impairment Coordinator
  18. Which class of fire involves ordinary combustible materials like wood and paper?
    A. Class B fires defined
    B. Class A fires defined
    C. Class C fires defined
    D. Class K fires defined
  19. What is the purpose of the “quick check” for portable fire extinguishers?
    A. To weigh the extinguisher unit
    B. To test the discharge nozzle
    C. To verify the PFE tag color
    D. Monthly visual inspection for readiness
  20. Who must perform the annual inspection of portable fire extinguishers?
    A. A W-96 C of F holder
    B. The building maintenance staff
    C. An FDNY inspector personnel
    D. The S-95 C of F holder
    Answer Key:
    -11. A
    -12. B
    -13. D
    -14. B
    -15. D
    -16. C
    -17. D
    -18. B
    -19. D
    -20. A
  21. Where should the alarm log book be maintained?
    A. Kept in the owner’s office
    B. At the main FACP location
    C. Stored off-site for safety
    D. With the building security desk
  22. What type of signal does a sprinkler valve tamper switch typically generate?
    A. Generates a fire alarm signal
    B. Generates a trouble signal always
    C. Generates no signal directly
    D. Generates a supervisory signal
  23. What does the “ACK” button on an FACP do?
    A. Acknowledges signals received
    B. Silences all audible alarms only
    C. Resets the entire system immediately
    D. Takes the system fully offline
  24. What is the function of the Alarm Silence switch?
    A. Resets the alarm initiating device
    B. Acknowledges a trouble condition
    C. Sends test signal to central station
    D. Silences building notification appliances
  25. When should the System Reset switch be used?
    A. Used immediately upon alarm activation
    B. Used after alarm condition is cleared
    C. Used only by FDNY personnel
    D. Used to test the panel lights
  26. Which type of smoke detector uses a radioactive source?
    A. Photoelectric light-scattering detectors use it
    B. Projected beam-type detectors use it
    C. Air-sampling type detectors use it
    D. Ionization detectors use it
  27. What is the purpose of duct smoke detectors?
    A. To detect heat in ducts primarily
    B. To sample air for humidity levels
    C. To prevent smoke spread via HVAC
    D. To activate the sprinkler system
  28. What action do fixed-temperature heat detectors usually require after activation?
    A. Require simple manual resetting
    B. Require cleaning of the sensor
    C. Require recalibration by technician
    D. Require replacement typically
  29. What initiates a signal from a waterflow alarm device?
    A. Flow of water in sprinklers
    B. Low water level detection
    C. High water pressure detection
    D. Manual switch activation only
  30. Can an S-95 holder perform repairs on a central station transmitter?
    A. Yes, minor repairs allowed
    B. No, requires electrician license
    C. Yes, if trained by company
    D. No, prohibited from repairs
    Answer Key :
    -21. B
    -22. D
    -23. A
    -24. D
    -25. B
    -26. D
    -27. C
    -28. D
    -29. A
    -30. D

Let’s Get Started With S-95 Fitness Certificate Practice Test with Answers Sheet

Special Requirements for the S-95 Fitness Certificate.

Individuals who have obtained any of these certificates will be exempt from obtaining a separate fitness certificate for the same building.

Also, anyone who has a certificate from, can obtain an S-95 for a different building but with a letter of recommendation from the employer and a payment of $25.

Exam S-95 Fitness Certificate tips.

The S-95 examination will consist of 35 multiple- option questions, administered on a “ touch screen” computing device video display. it’s a time- restrict examination. in keeping with the quantity of the questions, you will have 53 minutes to finished the check. A casual ranking of at least 70% is needed so as to cozy a certificates of health. call (718) 999-1988 for additional info and forms. please all the time examine for the current revised booklet at FDNY web page before you are taking the examination.

The Exam Material Info…

This course will help you prepare for the Fire Alarm Physical Fitness Certification Exam. It includes many sources, but this course will not cover all the information you will need for your job. You will certainly need additional information either from outside sources or through experience.

All the information you need to work on fire alarm systems that is not in the official manual provided to you will be your responsibility to learn, such as the laws and regulations in force in New York City and everything about the fire systems in the building for which you are responsible.

All test questions will consist of four multiple choice questions with one answer. If you leave a question blank, your answer will be considered incorrect. A passing score of 70% or higher is required to pass the test.

Scroll to Top